contact us Contact us
contact number: 010-82482526/27/28
company address: 北京市海淀区马连洼北路8号万霖科技大厦B座709室

scan it Get more details
Home >>  Product Center

NGT-HTR


The NGT-HTR gamma sensor is designed to operate in severe, high temperature drilling environments such as those found in Haynesville and Eagle Ford. It is fully operational to 190°C with a vibration specification that is 25% higher than competing tools on the market. The high temperature rating reduces gamma count drift ensuring accurate CPS in hot wells.
Product Details

NGT-HTR High Temperature/Ruggedized, Non-Directional Gamma Tool (1.36” OD)

The NGT-HTR gamma sensor is designed to operate in severe, high temperature drilling environments such as those found in Haynesville and Eagle Ford. It is fully operational to 190°C with a vibration specification that is 25% higher than competing tools on the market. The high temperature rating reduces gamma count drift ensuring accurate CPS in hot wells.

The NGT-HTR represents the next generation of downhole directional drilling gamma sensor technology. A complete electrical and mechanical redesign of our industry standard NGT-T gamma tool, the new NGT-HTR drops directly into legacy based MWD systems. Electronics and thru-wires are fully enclosed to improve reliability and external noise isolation. The new single board electronics are cushioned between pre-molded pads, providing superior shock and vibration protection and eliminates potential thermal expansion of flowed potting materials around and under electronic components.

Designed for compatability with Tensor style MWD systems, the NGT-HTR utilizes high temperature 15-pin Micro-D Subminiature (MDM) connectors on the top (male pin) and bottom (female socket) with all wires passed through. Battery power is supplied at Pin 4 with Ground at Pin 1. Output gamma pulses are at Pin 8.

To protect your gamma investment and ensure the best performance use CBG original MWD Shock/Vibration Isolator.


                              NGT-HTR Specifications    P/N 200-100-000

DetectorScintillator CrystalSodium Iodide, Na(TI)
PhotomultiplierR3991A (Hamamatsu)*
MechanicalDiameter (OD)1.36”
Length (make-up)13.6”
Weight1.7 lb.
End ConnectorsMicro-D Subminiature, 15-Pin
MaterialAluminum Alloy
PerformanceSensitivity1.14 CPS/API**
Accuracy+/- 5% to 150°C
+/- 15% to 190°C
EnvironmentalOperating Temperature-18°C to 190°C
Survival Temperature (reduced accuracy)-40°C to 200°C
Heat/Cool Rate, Max.2.8°C (5°F) per minute
Vibration (3 axis) 50-1000Hz, Random35G (25G RMS)
Shock (3 axis)1000G, 0.5ms, half-sine
Power RequirementsDC Input Voltage10-50 VDC
Tool Current (at 28V)10 mA at 24°C
20mA at 190°C
Output SignalNegative Pulse+5V to GND, 5 uSec width


* Available upon request with R3991AH (Hamamatsu) PMT as P/N 200-101-100
** Counts are collected with gamma tool mounted within a standard BeCu pressure barrel, (OD 1.875′, ID 1.500′). API Calibration performed with AEA Technology, QSA Inc., KUTh Field Verifier #188074, S/N 255 Radionuclides: K-40 (11.7%), U-238(90 ppm), Th-232(40 ppm).